Lux levels by room: how many lux your home, desk and office need

Recommended lux levels: about 100 to 200 lux for living rooms and bedrooms, 50 to 100 for hallways and stairs, 250 to 500 on kitchen counters, 300 to 500 at a desk or for reading, and 500 for a normal office under EN 12464-1. Fine crafts need 800 lux or more. Measure at the surface you use.

Most homes are far dimmer than people think. A typical living room sits at 50 to 300 lux, a well-lit office reaches about 500, and the sun at sunrise already gives around 800. If your desk feels tiring or your kitchen counter is in shadow, the number is probably too low. Here is the target for every room and task, the standard each figure comes from, and how to check your own.

Home values come from IES residential guidance and similar design guides. Ranges are wide because rooms do many jobs: use the low end for general light and the high end where you read, cut or work.

Room or taskLuxFoot-candlesWhat to aim for
Hallway50 to 1005 to 10Enough to see the floor and the walls
Stairs50 to 1005 to 10Even light on every tread, no dark steps
Living room, general100 to 20010 to 20Soft overall light
Dining room100 to 20010 to 20Brighter over the table than the edges
Bedroom, general100 to 20010 to 20Low and warm
Bedroom, reading in bed200 to 30020 to 30A lamp aimed at the page
Kitchen, general150 to 20015 to 20Ceiling light that fills the room
Kitchen counters250 to 50025 to 50Under-cabinet or pendant light
Bathroom, general200 to 50020 to 50Bright enough to clean
Bathroom mirror500 or more50 or moreLight on the face from the front
Home office, general15015Fills the room around the desk
Desk, reading and writing300 to 50030 to 50Measured on the desk surface
Workshop, garage bench300 to 75030 to 70Higher for small parts
Fine sewing, crafts, models800 to 1,000+75 to 100Task lamp close to the work

A rule that runs through every guide: the finer the detail and the lower the contrast, the more light you need. Reading large print on white paper is easy at 300 lux. Threading dark cotton through a needle wants 1,000.

Workplaces have written standards. In Europe, EN 12464-1 sets the required lux for each type of task. In North America, the IES Lighting Handbook is the reference most guides quote, and Canada's CCOHS publishes the same bands for health and safety checks.

Space or taskLuxStandard or guide
Corridors, walkways50 to 100IES; HSE quotes 50
Stairways50 to 100IES
Break rooms, lobbies100 to 300IES
Classrooms300 to 500IES
Conference rooms300 to 500IES
Normal office desk500EN 12464-1
Offices mostly on screensAverage of 500 or lessIES RP-1-04
Control room work300HSE HSG38
Kitchens, food preparation300 to 750IES
Engineering drawing750HSE HSG38
Professional laboratory750 to 1,200IES
Very small, low-contrast tasks1,000 to 2,000CCOHS

Two details matter here. First, screens change the picture: IES advises keeping the average at or below 500 lux where computer work dominates, because more light washes out the screen. Add a desk lamp for paper instead of brightening the whole office. Second, CCOHS says the lowest reading in a work area should be at least two-thirds of the average. A room can average 500 lux and still leave one desk in a 200 lux corner.

Why the numbers differ between sources

You will see a living room listed at 50, 100 or 215 lux depending on the page. That spread is real and has three causes.

  • Homes have no binding standard. IES residential values are design recommendations, not rules. Workplace standards such as EN 12464-1 apply to jobs, not lounges.
  • Taste and use. A living room used for reading needs more light than one used for TV.
  • Age. Older eyes let in less light. New Zealand's building research body BRANZ tells designers to raise levels for older occupants, and stairs and hallways are where it matters most.

Dark walls and floors swallow light too. Retail lighting guides add 10 to 20 percent more lumens for rooms with dark matte surfaces.

How to check the lux in your room

A lux target is useful only once you know where you stand. The method is simple:

  1. Turn the lights on and wait five minutes. Some bulbs start dimmer and climb.
  2. Measure at the surface you use: the desk top, the kitchen counter, or a point 76 cm (30 inches) above the floor for general light.
  3. Keep the meter or phone flat, facing up, and step back so your body does not shade it.
  4. Take four readings spread across the space and average them. Note the lowest one.
  5. Compare the average with the table, and the lowest reading with two-thirds of the average.

Measure daylight and electric light separately. A desk by a window can read 2,000 lux at noon and 150 at 7 p.m., and the evening figure is the one your lamps must cover. The full method, including the paper trick that makes a phone far more reliable, is in how to measure lux.

From lux to lumens: fixing a dark room

Once you know a room is short, the fix is a lumens question. Lux is lumens per square metre, so a rough target is the lux you want times the floor area in square metres. A 3 by 4 metre bedroom at 150 lux needs about 1,800 lumens reaching the floor, and more from the bulbs because shades and walls absorb part of it. The lumens calculator does this for any room, and lux to lumens walks through worked examples. If the two units still blur together, lumens vs lux explains the difference in one picture.

Light colour by room

Brightness is half the story. Colour temperature, in Kelvin, sets the mood:

RoomColour temperatureFeel
Living room, bedroom, dining2,700 KWarm, relaxed
Bathroom, hallway3,000 KWarm but clean
Kitchen, home office, laundry3,500 to 4,000 KNeutral, alert
Garage, workshop5,000 KCool, crisp detail

For colour rendering, IES guidance asks for a CRI of 70 or more for comfort and 85 or more where colour matters, such as makeup, painting or cooking. Bulb makers call 90 and above excellent.

Evening is a different target

Every number above is for doing things. In the hours before bed, the goal flips: less light at the eye, warmer colour, lamps below eye level. A kitchen at 500 lux at 10 p.m. is good for chopping and bad for falling asleep. The evening and night levels are in how dark your bedroom should be.

Quick answers by room

  • Desk: 300 to 500 lux on the surface, 500 for long paper work.
  • Reading chair: 300 to 500 lux on the page from a lamp beside you.
  • Kitchen counter: at least 250 lux, 500 for detailed prep.
  • Stairs: at least 50 to 100 lux on every step, more for older family members.
  • Bathroom mirror: 500 lux or more on the face, lit from the front rather than from above.

Measure one room tonight. Most people find at least one space at half the level it should be, and a single lamp fixes it.

Questions people ask

How many lux do I need in an office?

A normal office workplace needs 500 lux on the desk under the European standard EN 12464-1, and IES guidance gives 300 to 500 lux. Where people mostly work on screens, IES advises keeping the average at or below 500 lux and adding a desk lamp for paper work.

How many lux do I need for reading?

Plan 300 to 500 lux on the page for comfortable reading, and up to 500 lux or more for small print or long sessions. A room's general light of 100 to 150 lux is too dim on its own, so a reading lamp aimed at the page does most of the work.

How many lux should a living room have?

A living room needs about 100 to 200 lux of general light. Home measurements show most evenings sit far lower at eye level, so add a lamp for reading corners and keep the overall level soft after dark.

Is 1,000 lux too bright for a room?

For a living space, yes: 1,000 lux is a workshop or detailed-craft level and will feel harsh in a lounge or bedroom. For fine sewing, model making or detailed repairs, 800 to 1,000 lux on the work itself is the right target.

How many lux does a kitchen need?

Give the kitchen 150 to 200 lux of general light and 250 to 500 lux on the counters where you cut and cook. Under-cabinet lights are the easiest way to bring counters up without making the whole room glare.

Sources

Made by EASYTECH, who also make LightMeter Pro.