Foot-candles to lux: multiply by 10.764 (and where foot-candles still rule)
To convert foot-candles to lux, multiply by 10.764: 50 foot-candles is about 538 lux. To convert lux to foot-candles, divide by 10.764: 500 lux is about 46 foot-candles. A foot-candle is one lumen per square foot, a lux one lumen per square metre, and a square metre holds 10.764 square feet.
Your plant tag says 200 foot-candles. Your phone reads 1,500 lux. Are you close? Multiply by 10.764, or for a fast answer, by 10. Here are the exact factors, tables both ways, and the places where foot-candles are still the working unit.
The conversion factor
- Lux = foot-candles × 10.764
- Foot-candles = lux ÷ 10.764 (or lux × 0.0929)
Why 10.764? Both units describe light landing on a surface. A foot-candle is one lumen per square foot. A lux is one lumen per square metre. One square metre holds 10.764 square feet, so a foot-candle packs 10.764 times more light into each unit of area.
The mental shortcut
- Foot-candles to lux: multiply by 10, then add 8 percent. 200 fc → 2,000 → about 2,150 lux.
- Lux to foot-candles: divide by 10, then take off 7 percent. 500 lux → 50 → about 46 fc.
Multiplying by 10 alone is close enough to judge a plant spot or a room; it is about 7 percent low. Multiplying by 11 is about 2 percent high.
Foot-candles to lux table
| Foot-candles | Lux | Typical example |
|---|---|---|
| 1 | 10.8 | One candle a foot away, the origin of the unit |
| 5 | 54 | Hallway, US construction corridor minimum |
| 10 | 108 | Living room general light |
| 20 | 215 | Bedroom or kitchen general light |
| 25 | 269 | Bottom of the low-light plant band |
| 30 | 323 | Office minimum under US construction rules |
| 50 | 538 | Desk, reading, kitchen counter |
| 75 | 807 | Workshop bench |
| 100 | 1,076 | Fine crafts; film set benchmark at T2.8 |
| 150 | 1,615 | Medium-light plant spot |
| 200 | 2,153 | Bright indirect plant spot |
| 300 | 3,229 | High-light plant minimum in some guides |
| 500 | 5,382 | Top of the medium-light plant band |
| 1,000 | 10,764 | Direct-light plants, full daylight in shade |
| 5,000 | 53,820 | Direct sun through a window |
| 10,000 | 107,639 | Direct summer sun outdoors |
Lux to foot-candles table
| Lux | Foot-candles |
|---|---|
| 10 | 0.9 |
| 50 | 4.6 |
| 100 | 9.3 |
| 150 | 13.9 |
| 200 | 18.6 |
| 300 | 27.9 |
| 500 | 46.5 |
| 750 | 69.7 |
| 1,000 | 92.9 |
| 2,000 | 185.8 |
| 5,000 | 464.5 |
| 10,000 | 929 |
| 25,000 | 2,323 |
| 100,000 | 9,290 |
For any other value, the lux and foot-candle converter does both directions and shows the room and plant band your number falls in.
Where foot-candles are still used
Lux is the international unit, but foot-candles hold on in four places, and each one is a reason you will meet them.
US lighting design and building rules
The IES, the main North American lighting body, has long published its recommendations in foot-candles, and US architects and electricians still think in them: 30 to 50 fc for an office, 5 to 10 fc for a hallway. OSHA's construction rule is written entirely in foot-candles, from 3 fc for excavation and access ways to 5 fc for corridors and warehouses, 10 fc for shops and 30 fc for offices and first aid stations. For lux values by room with the standard named, see lux levels by room.
Houseplant guides
Most US extension services describe plant light in foot-candles. The University of Florida's bands are a common reference: low light 25 to 100 fc, medium 100 to 500, high 500 to 1,000, direct sun over 1,000 for at least four hours. The same page notes that an office lit only by ceiling fixtures often sits at 40 fc or less, and that a north window may never reach 400 fc. Plant growers then often move on to PPFD and DLI; the how much light do plants need guide bridges all three.
Film and video sets
Gaffers and cinematographers use foot-candles because they connect neatly to exposure. The working benchmark: 100 fc gives a correct exposure at T2.8, ISO 100, 24 frames per second with a 180 degree shutter. Each doubling of ISO halves the light you need, and each stop you close the lens doubles it. At ISO 400, 25 fc is enough for T2.8. The light meter guide covers exposure metering in depth.
Older and US-made meters
Many handheld light meters sold in the US default to foot-candles, and some show both units. If a reading looks ten times too small or too large, check the unit first.
Foot-candles to lumens
Foot-candles and lumens are linked by area, in square feet:
- Lumens = foot-candles × square feet
- Foot-candles = lumens ÷ square feet
A 10 × 12 ft room at 20 fc needs 20 × 120 = 2,400 lumens landing on the floor, and more from the bulbs because shades and walls absorb part of the light. Lux to lumens has the full method with real rooms, and lumens vs lux explains the difference between the units.
How to measure foot-candles
A light meter or a phone app gives foot-candles directly. To get a reading that means something:
- Hold the meter or phone at the surface you care about: the desk, the counter, the top leaves of the plant.
- Face the sensor toward the light, flat on a desk or tilted toward a window for a plant.
- Keep your body out of the way, wait for the number to settle, and take three readings.
- Measure at the same time of day each time you compare spots.
The step-by-step method, including how to make a phone reading steadier and how to correct it against a known reference, is in how to measure lux. The steps are the same whatever unit the screen shows.
Questions people ask
How many lux is one foot-candle?
One foot-candle equals 10.764 lux. A foot-candle is one lumen spread over one square foot, and a square metre is 10.764 square feet, so the same lumen spread over a square metre gives that many times less light per unit of area.
Is 50 foot-candles bright?
For a room, yes. 50 foot-candles is about 538 lux, the level for a desk, a reading lamp or a kitchen counter, and close to a normal office. For plants it is low: even low-light houseplants do better at 50 to 100 foot-candles, and high-light plants want 500 or more.
How many lumens equal a foot-candle?
One foot-candle is one lumen per square foot. To light a surface to a given number of foot-candles, multiply by its area in square feet: 30 foot-candles over a 100 square foot room is 3,000 lumens landing on it, before the losses from shades and walls.
Can my phone measure lux or foot-candles?
Yes. A light meter app reads the light through the camera or the light sensor and shows lux or foot-candles. Treat the number as an estimate: hold the phone flat at the surface, cover the camera with white paper for a steadier reading, and correct it once against a known reference.
What is 10,000 lux equivalent to?
10,000 lux is about 929 foot-candles. It is the light of full daylight out of direct sun, or what a light therapy lamp gives at its rated distance. Indoor rooms sit around 50 to 500 lux, so 10,000 lux is twenty or more times brighter than a well-lit office.
Sources
- OSHA 29 CFR 1926.56: Illumination (construction) US minimum lighting levels written in foot-candles: 5 fc for corridors and warehouses, 10 fc for shops, 30 fc for offices and first aid stations.
- Archtoolbox: Recommended lighting levels in buildings IES lighting levels by space, listed in foot-candles and lux side by side.
- University of Florida IFAS Gardening Solutions: Light for houseplants Houseplant light bands in foot-candles: low 25 to 100 fc, medium 100 to 500, high 500 to 1,000, direct over 1,000.
- Neil Oseman: How big a light do I need? Cinematographers' benchmark: 100 foot-candles gives a correct exposure at T2.8, ISO 100, 24 fps with a 180 degree shutter.
Made by EASYTECH, who also make LightMeter Pro.