Lux to PPFD: the conversion factor for sunlight, white LEDs by color temperature, HPS and fluorescent

To convert lux to PPFD, multiply lux by a factor that depends on the light source: 0.0185 for sunlight, about 0.018 for a 2700 K white LED, 0.017 for 3000 K, 0.014 for 4000 K and cooler, 0.012 to 0.013 for HPS. So 10,000 lux of sunlight is about 185 µmol/m²/s.

Lux is how bright a room looks to you. PPFD is how much light a plant can use. You can get from one to the other with a single multiplication, as long as you use the factor for your light source. Use the wrong one and a grow light can read 30 percent stronger than it is.

The full table first, then why it works and how to use it.

The lux to PPFD factor table

PPFD (µmol/m²/s) = lux × factor. To go back, PPFD × (lux per µmol) = lux.

Light sourceFactor (µmol per lux)Lux per 1 µmol
Sunlight, daylight through a window0.018554
White LED, 2700 K (warm)0.018155
White LED, 3000 K0.017158
White LED, 4000 K (neutral)0.014370
White LED, 5000 K (daylight white)0.014668
White LED, color temperature unknown0.01567
Fluorescent, cool white or T50.013574
High-pressure sodium (HPS), standard0.012282
Double-ended HPS0.013077
Metal halide0.014171
Ceramic metal halide, 4200 K0.015465
Ceramic metal halide, 3100 K0.017059
Red and blue ("blurple") LED, or white with added redno reliable factorn/a

Neutral white LEDs measured in two separate studies came out at 0.0134 to 0.0137, so a cool white LED can sit slightly below its row. Some fluorescent tubes measure as low as 0.0117.

For foot-candles, multiply by 10.76 first: daylight works out to about 0.2 µmol per foot-candle, a 4000 K LED to about 0.15. The lux to PPFD calculator does both directions and shows the factor it used.

Treat every result as a band of about plus or minus 20 percent. If you read 200, write 160 to 240. That is plenty to set a lamp height or judge a window.

What is the difference between PPFD and lux?

Lux measures light as the human eye sees it, and PPFD counts the photons a plant can use. A lux meter weighs light the way your eye does. Its sensitivity peaks in green-yellow at 555 nm and drops steeply toward deep red and blue. PPFD counts every photon between 400 and 700 nm equally, because a plant uses red and blue photons at least as well as green ones.

So two lamps with the same lux can feed a plant very differently. In a 2023 study that measured lamp spectra, 1,000 lux equaled 9.5 µmol from a green LED, 13.5 from a neutral white LED, 32 from a red LED and 82 from a violet one. White light sits in a narrow, predictable range, which is why lux works well for white lamps and daylight. Narrow red or blue light breaks the conversion.

Warm white LEDs carry more red photons per lux than cool ones. That is why the factor rises from about 0.014 at 4000 K to about 0.018 at 2700 K.

Worked examples

A bright window. You read 5,400 lux beside a north window at noon. 5,400 × 0.0185 = 100 µmol/m²/s. Plenty for a monstera.

A 4000 K LED panel over herbs. 14,000 lux at the canopy. 14,000 × 0.0143 = 200 µmol. Using the sunlight factor would have said 259, and you would have hung the light too high.

A 3000 K bulb over a shelf. 12,000 lux × 0.0171 = 205 µmol. Warm light gives more PPFD per lux than you might expect.

The other way: what lux for 300 µmol? Under a 4000 K LED, 300 × 70 = 21,000 lux. In sunlight, 300 × 54 = 16,200 lux.

From PPFD to the daily dose. 200 µmol for 14 hours: 200 × 14 × 0.0036 = 10.1 mol/m²/day of DLI. What is DLI explains why that number matters more than the reading itself.

How to get a good lux reading first

The factor is only as good as the lux number you feed it.

  1. Measure at the leaves, at canopy height, never at the lamp.
  2. Face the sensor toward the light. Lay white copy paper flat at canopy height and aim the camera at it, or cover the front camera with the paper and point the screen up at the lamp.
  3. Turn off other lights and close the blinds when you measure a lamp. A 3000 K bulb mixed with daylight has no single factor.
  4. Let the lamp warm up: about 10 to 15 minutes for LEDs, longer for fluorescent and HID.
  5. Read the center and the edges. Edges usually read well below the center.

Under white LEDs, read the lux and apply the factor for the lamp's color temperature from the table, since one LED factor cannot fit every white LED. The step by step for houseplants lives in measure plant light with your phone.

When to skip the conversion

  • Red and blue or red-heavy lamps. Use the maker's PPFD chart at your hanging height.
  • Mixed sources, such as a grow light near a sunny window. Measure each with the other off, or measure at night for the lamp.
  • Critical crops near their limit, where 20 percent matters. Do you need a PPFD meter covers when a quantum sensor pays off.

For everything else, a lux reading, the right row of the table and a sense of the target band will tell you whether to move the plant, lower the lamp or leave it alone. Targets by plant are in how much light do plants need.

Questions people ask

What is 1,000 PPFD in lux?

About 54,000 lux in sunlight, about 70,000 lux under a 4000 K white LED and about 82,000 lux under a standard HPS lamp. The same plant light reads very differently in lux depending on the source, which is why the factor matters.

How many lux is 300 PPFD?

About 16,200 lux in sunlight, 17,500 lux under a 3000 K white LED and 21,000 lux under a 4000 K white LED. For seedlings and leafy greens, 300 PPFD at the canopy is a solid target.

Can you convert lux to PPFD for a red and blue grow light?

Not reliably. Lux barely counts deep red and blue light, so the same lux reading can hide two to six times more PPFD under a red and blue lamp than under a white one. Use the maker's PPFD chart or a quantum sensor for these lights.

How much lux is too much for plants?

For shade houseplants such as calathea, ferns and peace lily, hours of direct sun above about 10,800 lux (1,000 foot-candles) start to scorch leaves. Under grow lights, most plants without added CO2 gain little above about 1,000 PPFD, roughly 54,000 lux of sunlight or 70,000 lux from a 4000 K LED.

Can my phone measure lux?

Yes. A light meter app reads lux from the phone's camera. Treat it as an estimate: it is reliable for comparing spots and finding which light band a plant sits in, and it gets closer to a real meter if you calibrate it once. Below about 100 lux phone readings get rough.

Sources

Made by EASYTECH, who also make LightMeter Pro.